h/p/cosmos gaitway 3D Instrumented Treadmill Ergometer

h/p/cosmos gaitway 3D Instrumented Treadmill Ergometer

SKU: cos3000201

The new gaitway 3D is a joint design by h/p/cosmos and Arsalis. It measures the ground reaction forces and torques in three directions and comes in three different sizes: each size is optimized for a range of speeds.

The gaitway 3D offers a rigid construction to record optimal quality signals. The functionalities include a patient weighing scale, a recording of the ground reaction forces at rates up to 10 kHz, left and right force measurement for the vertical force during walking and an extensive list of biomechanical parameters of normal and pathological gaits.

Available for purchase upon enquiry.

If you would like more information on the product, or would like to purchase, please get in touch.

Contact HaB

h/p/cosmos logo.

Not Quite Right?

Check out the brand page for more products from this manufacturer

gaitway 3D Instrumented Treadmill

The h/p/cosmos® gaitway 3D Instrumented Treadmill is different and consists of one large single platform that does not have a split belt. It is available in different running deck sizes like 150/50, 170/65 and 190/65cm.

As running consist of single contact phases (just one foot on the ground at a time), the treadmill is perfect to measure forces also at higher speeds. The ample running surface encourages a natural running position. Moving slightly forward or sideward does not affect the measurement accuracy.

Also when walking on the treadmill, the subjects do not need to worry about the position. They are not required to place the heel on the front belt, nor are they forced to hit the right belt with the right foot and vice versa. When walking on a single platform, the load cells will measure a sum of left and right limb forces, but only in the double stance phase. A dedicated algorithm can decompose this sum. The procedure was published some years ago and improved in subsequent years (Davis & Cavanagh, 1993; Dierick et al, 2004; Meurisse et al, 2016, Raison et al, 2005). This algorithm is validated now for both healthy and clinical gait and published in highly rated journals.

gaitway 3D System performance Features

  • Extremely wide measuring range
  • Excellent measuring accuracy
  • Built-in amplifier with acquisition system
  • LAN connection
  • Control & acquisition software included
  • Start and stop trigger inputs and digital trigger output for integration with EMG and motion analysis systems
  • Raw data accessible via interface
  • Cost-effective
  • Also available in economic 1 component ground reaction force Fz version incl. 25% inclination (h/p/cosmos treadmill gaitway III)

Used by Carnegie School of Sport, Leeds Beckett University

Additional information

Shipping/Delivery Restrictions

Can only be shipped to UK and Ireland

Features

Biomechanical Parameters:

  • Step length, width, frequency
  • Swing / stance durations
  • Contact / aerial durations
  • Stride asymmetry
  • Force peaks (push-off, landing)
  • Force vector orientation
  • Loading and unloading rate
  • Left / Right foot for vertical force
  • More biomechanical parameters
  • Online feedback to user (e.g. for training facilities)
  • Data recording & analysis (e.g. for research facilities)
  • Patient evaluation (e.g. for clinical research facilities)

Measured and Computed Signals:

  • 3D Force (Fz, Fy, Fx)
  • Center of Pressure (Opx, Opy)
  • Moments (Mx, My)
  • Frictional Torque (Tz)
  • Belt speed

Resources

Click the image below to download the full gaitway 3d brochure:

Videos

Reviews

There are no reviews yet.

Be the first to review “h/p/cosmos gaitway 3D Instrumented Treadmill Ergometer”

We're Here To Help

Our knowledgeable and experienced team are here to listen to your requirements, guide you through your various options and advise you as to which specific solution would best suit your needs.

Email opt-in
This field is for validation purposes and should be left unchanged.

Newsletter Signup

Tick any specific interest
This field is for validation purposes and should be left unchanged.