EKF Diagnostics Biosen Blood Glucose/Lactate Analyser

EKF Diagnostics Biosen Blood Glucose/Lactate Analyser

SKU: BIOSEN-C

The Biosen C-Line, is a glucose/lactate blood analyser used extensively in universities, laboratories, hospitals, diabetes clinics and professional sports teams around the world.

Biosen C-Line analysers are available in three versions, each with the option of single channel (1-channel), for testing glucose or lactate, or dual channel (2-channel) for testing glucose and lactate together: Biosen C-Line GP (5 sample positions) and Biosen C-Line Clinic (20 sample positions)

Available for purchase upon enquiry.

If you would like more information on the product, or would like to purchase, please get in touch.

Contact HaB
Clear

Not Quite Right?

Check out the brand page for more products from this manufacturer

EKF Diagnostics Biosen Blood Glucose/Lactate Analyser

EXCLUSIVE TO HaB DIRECT IN THE UK AND IRELAND, the Biosen blood glucose/lactate analysers by EKF Diagnostics are market leading bench-top analsyers used by universities, research centres, hospitals, diabetes clinics and professional sports teams around the world. Being simple and easy to use, Biosen blood glucose/lactate analysers have established themselves as the product of choice for most of the UK’s leading Sport Science establishments, with the devices high accuracy and dependable reliability touted as one of the main reasons customers decided to purchase their Biosen device.

Biosen devices uses special enzymatic-amperometric chip sensor technology to deliver fast results (20- 45 seconds) and up to 120 results per hour, with a high degree of accuracy (2% CV) and a low cost per test. Due to the long life of the sensor chip (Glucose: up to 60-days/7,500 tests; Lactate: up to 50-days/6,000 tests), the system requires little maintenance. Features such as the multi-lingual touch screen display with step-by-step instructions and large memory (up to 1,000 results) only add to the Biosen analyser’s user-friendliness.

Requiring just a 20 μl sample, the Biosen can test blood, plasma or serum to provide glucose and lactate values with excellent precision (less than 2% CV) over a wide measurement range (Glucose: 0.5 – 50 mmol/L; Lactate: 0.5 – 40 mmol/L). Unlike other blood analyser’s, Biosen samples remain stable for up to five-days (refrigeration recommended).

All Biosen analysers are supplied with an interface to connect to hospital or lab information systems (LIS). An integrated barcode reader and printer are also available with most configurations.

Haemolysis solution can be found here.

A study titled “Comparison of Postprandial Glycaemic Response Following White Bread Meal Consumption between Healthy Young Asian and White Caucasian Adults” using the Biosen Blood Glucose/Lactate Analyser sheds light on crucial dietary responses across different ethnicities.

Additional information

Results

20 – 45 seconds

Results storage

Up to 1,000 results

Imprecision

< 1.5% CV

Display

Multi-lingual with step by step instructions

Sensor Life

Glucose 60 days / 7,500 tests, Lactate 50 days / 6,000 tests

Measuring Range

Glucose 0.5–50 mmol/L (9–900 mg/dL), Lactate 0.5–40 mmol/L (5–360 mg/dL)

Model

Biosen C-Line GP (Single Channel), Biosen C-Line GP (Dual Channel), Biosen C-Line Clinic (Single Channel), Biosen C-Line Clinic (Dual Channel), Biosen C-Line Clinic (Single Channel) with barcode scanner, Biosen C-Line Clinic (Dual Channel) with barcode scanner, Biosen S-Line Lab (Single Channel) with barcode scanner, Biosen S-Line Lab (Single Channel), Biosen S-Line Lab (Dual Channel) with barcode scanner, Biosen S-Line Lab (Dual Channel)

Shipping Restrictions

Can only be shipped to UK and Ireland

Features

  • Results in 20-45 seconds</li>
  • Up to 120 result
  • s an hour
  • Imprecision 1.5% CV
  • Biosen C-Line: 280 x 280 x 95 mm
  • Biosen S-Line: 440 x 340 x 168 mm
  • 5-8 kg depending on Biosen Analyser model
  • Pre-filled ‘Safe-Lock’ reaction cups eliminate manual dilution
  • Enzymatic-amperometric method using chip-sensor technology
  • Chip sensors easily exchangeable, no electrode cleaning required
  • Innovative needle and exchanger design eliminates cross contamination
  • Three calibration modes
  • Measurement is easy and takes just three steps

Resources

Click the image below to download the product sheet:</p>

 

Research

A  study titled “Comparison of Postprandial Glycaemic Response Following White Bread Meal Consumption between Healthy Young Asian and White Caucasian Adults” using the Biosen Blood Glucose/Lactate Analyser sheds light on crucial dietary responses across different ethnicities. 

Videos

 

 

Reviews

There are no reviews yet.

Be the first to review “EKF Diagnostics Biosen Blood Glucose/Lactate Analyser”

We're Here To Help

Our knowledgeable and experienced team are here to listen to your requirements, guide you through your various options and advise you as to which specific solution would best suit your needs.

Email opt-in
This field is for validation purposes and should be left unchanged.

Newsletter Signup

Tick any specific interest
This field is for validation purposes and should be left unchanged.